According to "DL/T 320-2010 General Technical Requirements for Personal Arc Protective Equipment", the protection level of anti-arc clothing generally adopts the ATPV value. The first layer has an ATPV value of 4, the second layer is 8, the third layer is 25, and the fourth layer is 40. Under normal circumstances, single-layer arc protective clothing requires the ATPV value to reach two levels, and multi-layer fireproof clothing and flash clothing can reach three and four levels.


According to the degree of danger of the working environment, arc suits are generally divided into the following four levels

Class I: 4cal/cm2 less than or equal to ATPV <8 cal/cm2

Class II: 8 cal/cm2 less than or equal to ATPV <25 cal/cm2

Class III: 25 cal/cm2 less than or equal to ATPV <40 cal/cm2

Class IV: ATPV value greater than or equal to 40 cal/cm2. Level 4 has the highest degree of protection.

According to "DL/T 320-2010 General Technical Requirements for Personal Arc Protective Equipment", the protection level of anti-arc clothing generally adopts the ATPV value. The first layer has an ATPV value of 4, the second layer is 8, the third layer is 25, and the fourth layer is 40. Under normal circumstances, single-layer arc protective clothing requires the ATPV value to reach two levels, and multi-layer fireproof clothing and flash clothing can reach three and four levels.


According to the degree of danger of the working environment, arc suits are generally divided into the following four levels

Class I: 4cal/cm2 less than or equal to ATPV <8 cal/cm2

Class II: 8 cal/cm2 less than or equal to ATPV <25 cal/cm2

Class III: 25 cal/cm2 less than or equal to ATPV <40 cal/cm2

Class IV: ATPV value greater than or equal to 40 cal/cm2. Level 4 has the highest degree of protection.


Risk level

Applicable positions

tanncot products

Class I

6-8cal/cm2

Open the cover of the 240V and below power distribution cabinet, and operate the circuit breaker or fuse switch

6cal

Class II

8-25cal/cm2

Confined space operation circuit breakers and fuse switches for 600V voltage class MCC 

8cal,12cal

120V and below live circuits; unshielded operating at 1kV with metal-covered switchgear

8cal,12cal

 

Class III

 25-40cal/cm2

600V switchgear (with power circuit breaker or fuse switch), insert or remove breaker, open cabinet door

25,33cal

Class IV

 40cal/cm2above

Starters for high voltage motors of 3000V and above, remove cover bolts

40cal,65cal


6380099580547982703458152.png

DL/T 320-2010 General technical requirements for personal arc protective equipment download

"DL/T 320-2010 General technical requirements for personal arc protective equipment"



Related News
2022 1st Fenket "Make Better FRC" Tooling Design Competition ended perfectly!
2022 1st Fenket "Make Better FRC" Tooling Design Competition ended perfectly!
2022-11-12
为进一步深化纤科特(广东)特种服装有限公司和广东南方职业学院的校企合作,切实促进学院技能型人才的培养,满足企业对服装设计的市场需求,2022年度第一届纤科特“Make Better FRC”工装设计大赛应运而生。 ……
Good news|Congratulations to our company's self-designed one-piece workwear for obtaining the national utility model technology patent!
Good news|Congratulations to our company's self-designed one-piece workwear for obtaining the national utility model technology patent!
2022-11-12
Recently, Tanncot (Guangdong) Special Garment Co., Ltd.The self-designed and developed &quot;a breathable and ventilated jumpsuit&quot; won the national utility model patent. This clothing solves the pain points of weari……
Tanncot teach you how to wear fire suits
Tanncot teach you how to wear fire suits
2022-11-10
Firefighting suit is one of the important equipment to protect firefighters. It can prolong the time to escape from the fire and protect the personal safety of firefighters. Today, Xiaobian will tell you how to wear fire……